BERETTA WALL-MOUNTED BOILER Open chamber MYNUTE 24 CAI LX Low Nox 24 kw METHANE cod. 20151436
BERETTA WALL-MOUNTED BOILER Open chamber MYNUTE 24 CAI LX Low Nox 24 kw METHANE cod. 20151436 is backordered and will ship as soon as it is back in stock.
Couldn't load pickup availability
How shipping works
How shipping works
Shipping costs vary depending on the weight and shipping method of the order.
Our shipping services
Standard Shipping: estimated delivery in 2 to 5 working days
Premium Shipping: guaranteed delivery in 24 working hours
Premium Shipping + Flat Delivery: guaranteed delivery in 24 working hours
Please refer to the tables for Standard Shipping prices for Italy and for Minor Islands and Disturbed Areas.
For further details on Premium Shipping, please see the Premium Shipping page.
Customer service
Customer service
Our service department is dedicated to providing support to our customers for any problems or questions they may have before or after purchasing our products.
Use the direct communication channel to speak to one of our operators, or send us an e-mail to one of the addresses listed on the contact us page.
Our customer service team consists of highly qualified professionals who are always ready to help customers solve any problems or answer any questions quickly and efficiently. We strive to ensure maximum customer satisfaction and provide the highest quality after-sales service. So, if you need assistance, please do not hesitate to contact us; we will be happy to help you in any way we can.
Description
Description
BERETTA WALL-MOUNTED BOILER Open chamber MYNUTE 24 CAI LX Low Nox 24 kw METHANE cod. 20151436
Mynute LOW NOX
- Nominal heat input kW 25.80
- Nominal heat output (80 - 60 °C) kW 24.05
- Reduced heat output (80 - 60 °C) kW 11.28
- Reduced heat output kW 12.5
- Electrical power 115 Watts
- Supply voltage / frequency Volt/Hz 230 / 50
- IP X5D electrical protection rating
- Useful efficiency at Pn max ((80 - 60 °C) % 93.2
- Useful efficiency at 30% Pn (47 °C return) % 91.8
- POLLUTING EMISSIONS (G20)
- NOx according to UNI EN 483 class 5
HEATING OPERATION
- Maximum pressure and temperatures bar/°C 3 / 90
- Heating temperature selection range °C 40 / 80
- Pump: pump head available for the mbar 275 system
- at a flow rate of 1000 litres/h
- Expansion tank capacity 9 litres
HEALTHCARE EXERCISE
- Maximum pressure bar 6
- Minimum pressure 0.15 bar
- Quantity of hot water with ∆t=25°C litres/min 14
- Minimum domestic water flow litres/min 2
- Domestic hot water temperature selection field °C 37 - 60
CONNECTIONS
- Heating inlet - outlet Ø 3/4”
- Sanitary inlet - outlet Ø 1/2”
- Gas inlet Ø 3/4”
COAXIAL SMOKE EXHAUST AND AIR INTAKE PIPES
- Diameter 60 - 100 mm
- Maximum length 2.5 m
- Loss for the insertion of a 90° / 45° bend m 1.5 / 1
SEPARATE SMOKE EXHAUST AND AIR INTAKE PIPES
- Diameter 80 + 80 mm
- Maximum length 14 + 14 m
- Loss for the insertion of a 90° / 45° bend m 1.7 / 1.2
- DIMENSIONS, WEIGHT, GAS
- Boiler size (HxWxD) 780x400x338 mm
- Weight 35 kg
Beretta MYNUTE 24 CAI LX wall-mounted boiler
- instantaneous combined open natural draft, methane,
- Thermal flow rate Heating 24kW and DHW (l/min-?t 25°C) 14,
- with low Nox emissions, specifically designed to facilitate the replacement of pre-existing wall-mounted boilers,
Simple and intuitive digital display.
Technical features:
- New boilers with low NOx emissions
- Low consumption circulator (EEI?0.20) as standard
- Specially designed to facilitate the replacement of pre-existing wall-mounted boilers
- 9 liter expansion vessel
- Simple and intuitive digital display
- Predisposition for climate thermoregulation (optional external probe) Predisposition for connection to the BeSMART Comfort control (code 20143539)
- IPX5D electrical protection degree
- Hydraulic fittings, gas and sanitary taps (optional)
The ecological burner
- To achieve high standards
- Mynute Low NOx is equipped with a
- special atmospheric burner,
- cooled and equipped with numerous nozzles
- higher, which allows specification
- premixing of gas and air. In this
- way combustion occurs a
- lower temperatures than what happens
- in a traditional burner. The burner
- is composed of a surface on the
- which the high flame develops few
- millimeters, also called “microflame”.
- The tube that crosses the burner with
- the return water from the system
- heating promotes cooling
- of the burner surface.
Product Warranty The warranty on this item is 24 months from the date of purchase.
Specifications
Specifications
- peso: 35.0 kg
- classe efficienza energetica: A
- classe energetica produzione acs: B
- classe energetica riscaldamento: A
- costospedizionecad: IT25;AD113;AT73;BE75;BG88;HR89;DK125;EE122;FR94;DE63;LV94;LT88;LU59;NL68;PT82;CZ66;SK73;SI74;ES75;SE131;HU56;CH135;
- gas: Methane
- marca: Beretta
- metri quadri : 120
- modello: 20151436
- potenza in kw: 24
- potenza nominale: 24
- superficie riscaldabile mq: 120