OPPORTUNITY AREA Ferroli Condensing Boiler DIVACONDENS D PLUS F24 Methane LOW NOx Complete with fume exhaust kit - NEW ErP
OPPORTUNITY AREA Ferroli Condensing Boiler DIVACONDENS D PLUS F24 Methane LOW NOx Complete with fume exhaust kit - NEW ErP is backordered and will ship as soon as it is back in stock.
Couldn't load pickup availability
How shipping works
How shipping works
I costi di spedizione variano a seconda del peso e della modalità di spedizione dell'ordine.
I nostri servizi di spedizione:
- Spedizione standard: consegna stimata dai 2 ai 5 giorni lavorativi
- Spedizione Premium: consegna garantita in 24 ore lavorative
- Spedizione Premium + Consegna al piano: consegna garantita in 24 ore lavorative
Consulta le tabelle per i prezzi della spedizione standard per l'Italia e per le Isole Minori e Zone Disagiate.
Per ulteriori dettagli sulla Spedizione Premium, consulta la pagina di spedizione premium.
Servizio clienti
Servizio clienti
Il nostro servizio di assistenza è dedicato a fornire supporto ai nostri clienti per qualsiasi problema o domanda che possano avere prima o dopo l’acquisto dei nostri prodotti.
Utilizza il canale di comunicazione diretta per parlare con un nostro operatore, oppure inviaci una mail ad uno degli indirizzi elencati nella pagina contattaci.
Il nostro team di assistenza clienti è composto da professionisti altamente qualificati e sempre pronti ad aiutare i clienti a risolvere qualsiasi problema o rispondere a qualsiasi domanda in modo rapido ed efficiente. Ci impegniamo a garantire la massima soddisfazione del cliente e a fornire un servizio di assistenza post-vendita di altissima qualità. Quindi, se hai bisogno di assistenza, non esitare a contattarci; saremo lieti di aiutarti in ogni modo possibile.
Description
Description
ATTENTION THE PRODUCT IS NEW AND 100% WORKING, BUT IT HAS SIDE AND FRONT DENTS (SEE PHOTO NEXT TO THE MAIN IMAGE)
ATTENTION ! The boiler will be supplied with methane, for LPG operation you must contact your local Authorized Assistance Centre.
Technical features
- Model: Divacondens D Plus
- Nominal thermal power: 24 kW
- Fuel: Methane
- Heating Energy Efficiency Class: B
- Seasonal Energy Efficiency for Space Heating: 89%
Performance
- Heating heat output: 7.5 ~ 25.0 kW
- Heating Thermal Power: 7.2 ~ 24.2 kW
- Useful Thermal Efficiency 30% Pmin: 100.1 %
- Domestic Hot Water Production 25°C ?t 30°C: 13.9 ~ 11.6 l/min
- NOx emissions 6
- Dimensions (LxHxD): 400x700x330 mm
- Weight: 35 kg
The Range
Divacondens D Plus is offered in a single model for heating and instant production of domestic hot water
Characteristics
> Condensing boiler for heating high temperature systems and producing domestic hot water. It is not suitable for combination with direct delivery to systems with low temperature radiant panels
> Compact geometry primary exchanger
> Instant production of domestic hot water with dedicated plate exchanger
> Post-recovery of the latent condensation heat, acting as pre-heating of the primary circuit
> Sealed chamber and forced draft boiler, with water-cooled atmospheric burner with low NOx emissions
> Automatic hydraulic by-pass as standard
> Minimum polluting emissions (class 6 according to EN 15502-1)
> High efficiency, low consumption circulator (ErP - Class A) with anti-blocking system activated for a few seconds every 24 hours of inactivity
> Can be combined with the modulating remote timer control
> Simple and complete control panel, user interface on display, with setting keys
> Robust post-capacitor powered by the closed primary circuit. The heat exchange with the fumes takes place inside large diameter water passages.
> Generator with simple and rational operation
> ECO function in domestic hot water for greater savings in periods of low use of hot water
> Preparation for solar systems: predisposed for the production of domestic hot water combined with solar panel systems
> Place of installation: also outdoors in a partially protected place down to -5°C as standard
> Certified operation also with propane air (50% air - 50% G31) through a specific transformation to be requested from the Authorized Assistance Center
> Also works on LPG with the use of a specific conversion kit to be requested from the Authorized Assistance Center
Boiler control
The DIVACONDENS D PLUS control unit consists of an easy-to-use interface with a backlit display. Using the buttons it is possible to easily adjust the heating flow temperature, the domestic hot water set point, turn the generator on/off or activate the comfort function, monitoring the status of the boiler. The control panel is completed by a traditional pressure gauge which can check the system pressure at any time.
The performances
Energy classification DHW load profile (maximum flow rate at the corresponding efficiency declared in the DHW) Efficiency in the production of domestic hot water FOR COMBINATION BOILERS The "climate-energy 20/20/20" package provides ambitious objectives for reducing greenhouse gas emissions, of energy consumption as well as the increase in the use of renewable energy, corresponding to a percentage of 20% to be achieved by 2020. In this context, the European ErP (Energy Related Products) regulation introduces an energy classification also for water generators hot for space heating and domestic hot water purposes. This classification translates into an energy label which must necessarily accompany all products affected by the Regulation, introduced onto the market from 26 September 2015. The labeling constitutes an easy guide for the consumer, who can choose - through standardized and objective indications - the product more efficient. In this way the choice will be the most economical in terms of consumption for the benefit of the user, but also the most virtuous for energy balances and consequently for the environment. The most significant parameters indicated on the label are the seasonal efficiency index in heating and efficiency in the possible production of domestic hot water, according to a scale which in the case of the single boiler product ranges from A to G*. Furthermore, for combined boilers, a load profile is indicated corresponding to the DHW flow rate of the appliance measured in a series of standard withdrawals, guaranteeing at least the declared DHW efficiency. This index is identified with a letter/"size" (S, M ...XXL).
Solar circuit integration
DIVACONDENS D PLUS boasts electronics that simplify integration with solar thermal systems, both with natural and forced circulation. The microprocessor controls the temperature of the water coming from the solar circuit through the domestic hot water sensor and turns on the burner only if necessary. To reach the desired temperature, SUN EASY allows significant savings even during the coldest seasons, exploiting and integrating even the smallest solar contribution, which would otherwise be lost. In case of insufficient radiation and therefore modest pre-heating of the domestic water, the boiler will contribute the heat necessary to reach the required set point temperature. If the sun and the solar system fulfill their "duty", no integration by the boiler will be necessary, the hot water will be conveyed to the tap, without the need for additional devices, with the mixing of the thermostatic valves.
Safety and comfort
ANTI-FREEZE In the event that the temperature in the boiler drops to 5°C, the burner turns on automatically and the circulator activates in order to protect the appliance from damage caused by frost. This function is active with the boiler powered by the gas circuit and under electrical voltage.
POST-CIRCULATION This function allows you to recover all the heat supplied by the thermal inertia of the exchanger and transfer it to the heating system, and consequently to the rooms to be heated. This is a timer function (with customizable duration) and is active after the burner switches off in heating mode.
OPERATION IN SLIDING TEMPERATURE With the installation of the "External probe" kit it is possible to operate the boiler in sliding temperature. This means that without acting on the system temperature adjustment buttons, the boiler will self-regulate based on variations in external temperatures. All this translates into energy savings while ensuring maximum comfort for the user.
EASY CONTROL The DIVACONDENS D PLUS electronic board adopts the Opentherm protocol. It allows the integration of other peripheral control units such as, for example, the ROMEO remote timer control. The Opentherm standard has in fact been specifically designed to share the boiler's operating logic and algorithms with other additional control units. As a digital protocol, it allows for total integration between boiler and satellite, with full control of functions from the boiler and similarly from its satellite.
Product Warranty: All products on sale on our site are new and packaged. The warranty on this item is 24 months from the date of purchase.
Scheda Tecnica
Scheda Tecnica
- peso: 40.0 kg
- marca: Ferroli
- modello: AO580_1