Baxi Condensing Gas Boiler Model NUVOLA PLATINUM+ 24 GA with 40 Liter Methane or LPG Accumulation Complete with Fume Exhaust Kit
Baxi Condensing Gas Boiler Model NUVOLA PLATINUM+ 24 GA with 40 Liter Methane or LPG Accumulation Complete with Fume Exhaust Kit - Kit Fumi Coassiale is backordered and will ship as soon as it is back in stock.
Couldn't load pickup availability
How shipping works
How shipping works
I costi di spedizione variano a seconda del peso e della modalità di spedizione dell'ordine.
I nostri servizi di spedizione:
- Spedizione standard: consegna stimata dai 2 ai 5 giorni lavorativi
- Spedizione Premium: consegna garantita in 24 ore lavorative
- Spedizione Premium + Consegna al piano: consegna garantita in 24 ore lavorative
Consulta le tabelle per i prezzi della spedizione standard per l'Italia e per le Isole Minori e Zone Disagiate.
Per ulteriori dettagli sulla Spedizione Premium, consulta la pagina di spedizione premium.
Servizio clienti
Servizio clienti
Il nostro servizio di assistenza è dedicato a fornire supporto ai nostri clienti per qualsiasi problema o domanda che possano avere prima o dopo l’acquisto dei nostri prodotti.
Utilizza il canale di comunicazione diretta per parlare con un nostro operatore, oppure inviaci una mail ad uno degli indirizzi elencati nella pagina contattaci.
Il nostro team di assistenza clienti è composto da professionisti altamente qualificati e sempre pronti ad aiutare i clienti a risolvere qualsiasi problema o rispondere a qualsiasi domanda in modo rapido ed efficiente. Ci impegniamo a garantire la massima soddisfazione del cliente e a fornire un servizio di assistenza post-vendita di altissima qualità. Quindi, se hai bisogno di assistenza, non esitare a contattarci; saremo lieti di aiutarti in ogni modo possibile.
Description
Description
ATTENTION THE PRODUCT IS MADE TO ORDER. WILL BE SHIPPED WITHIN 10 WORKING DAYS FROM THE DATE OF PURCHASE.
ATTENTION THE BOILER IS SUPPLIED WITH METHANE. LPG OPERATION THROUGH ADJUSTMENT BY THE AUTHORIZED ASSISTANCE CENTER. FOR INFORMATION, CONTACT BAXI SUPPORT IN ADVANCE
Technical features
- ErP energy efficiency class (heating and DHW): A
- Load profile: XL
- Nominal DHW heat output kW 24.7
- Nominal heating heat output kW 20.6
- Nominal domestic hot water heat output kW 24
- Energy efficiency (92/42/EEC) ****
- Efficiency at 100% Pn (80-60°C): 97.6%
- Efficiency at 100% Pn (50-30°C): 105.4%
- Expansion/pre-charge vessel capacity l/bar 7.5/0.8
- Domestic water temperature adjustment °C 35-60
- Kettle capacity 40 litres
- Storage tank/pre-charge expansion vessel capacity l/bar 2/3.5
- Domestic water production ∆T 25°C l/min 13.8
- Domestic water production at discharge ∆T 30°C l/30' 385
- Degree of protection: IPX5D
- NOx class (EN 483) 5
- Dimensions (hxwxd): 950x600x466 mm; 65.5 kg
- Power supply: METHANE or LPG
Nuvola Platinum+
Total modulation pump
The Luna Platinum+ range is renewed with the introduction of a high-efficiency electronic pump with permanent magnet motor.
The new total modulation pump allows, compared to the use of a pump
Traditional modulating:
- Lower electricity consumption
- Better performance
- Greater durability
System deaeration
New electronic “system deaeration” function to facilitate the removal of air during first ignition.
Efficiency and savings
The objective of a heat generator is to provide the energy necessary for the rooms to maintain conditions of maximum comfort inside: this means providing the rooms, through the system, with the same quantity of heat that the building disperses . In newly constructed buildings, regulations increasingly require greater insulation and consequently less dispersion. Traditionally, there is a tendency to oversize heat generators to favor the production of domestic water: this leads to an excess of heating power which, together with the poor modulation capacity of traditional boilers, leads to discontinuous operation and therefore waste of fuel. Discontinuous processes generate energy losses (heat dispersion caused by pre-washing of the combustion chamber, wear of components caused by continuous on-off, decrease in generator efficiency). The modulation system of the Platinum+ range is able to adapt the thermal power produced to the actual power dissipated by the building, avoiding excessive overheating/cooling of the rooms.
Wide modulation range
Reduction of on-off cycles
The graph shown above highlights the reduction in on/off cycles that distinguishes the new Platinum+ boilers with modulation up to 1:10 compared to a condensing boiler with lower modulation. The reduction of on/off determines an improvement in the efficiency of the boiler and consequently a considerable saving for the end user. Standard condensing boilers, however, with a limited modulation range, work at a minimum power level above 6 kW; this allows it to avoid on/off cycles for only 3% of the heating operation period, compromising the performance of the boiler and the life of the components.
The electronics and the gas valve with stepper motor with which the new Platinum+ boilers are equipped guarantee automatic combustion control which is based on:
- on the flame signal
GAC via the flame signal
The system continuously measures the flame signal during boiler operation and adjusts the gas flow rate in order to maintain constant combustion quality and all this without requiring any additional component inside the combustion chamber.
Installers and end users benefit from the following advantages of GAC:
- The automatic combustion control helps reduce installation times as no manual adjustment of the gas valve or nozzle change is required: in fact, it is sufficient to manually modify some parameters of the electronic board for operation with LPG
- The boiler self-adapts to the quality of the gas and the length of the flue gas outlets: this means that there are no manual adjustments to make
- High modulation range 1:10: high efficiency and savings, as such a wide modulation range determines greater adaptability of the boiler to the heat losses of the building to obtain higher efficiency and greater durability of the components. The reduction of on/off cycles, in addition to greater efficiency, guarantees less noise produced by the boiler
- Unlike traditional condensing boilers, the boiler always works regulated at maximum efficiency values, favoring a reduction in gas consumption and consequently a lower environmental impact thanks to the control of CO/CO emissions
Power sets
The term Power set identifies the heating power regulation process according to the project data.
The heat output of the boiler, through the Power set device, is regulated according to energy needs: simply act on the control panel to adjust some parameters
Complete soundproofing
C-shaped structure
Silence means the relative or absolute lack of sound or noise. The noise level of the Luna Platinum+ boiler is comparable to a normal conversation
Digital pressure gauge
The electronic pressure transducer present in the hydraulic unit allows you to control the pressure directly on the display. Double alarm level in case of low pressure: a "warning" level in case of low pressure in the boiler; a “block” level in case of lack of pressure
Intubation solution
For renovating chimneys
Scheda Tecnica
Scheda Tecnica
- peso: 35.0 kg
- classe energetica produzione acs: A
- classe energetica riscaldamento: A
- gas: Methane/LPG
- marca: BAXI
- metri quadri : 120
- modello: Nuvola Platinum+ 24 GA
- potenza in kw: 24
- potenza nominale: 24
- superficie riscaldabile mq: 120
- tipologia : Ad accumulo