Hitachi Air Conditioning Ducted Ducted Inverter Primary series 48000 Btu RPIL-6.0UFE1NH + RAS-6.0UFESNH1 R-32
Hitachi Air Conditioning Ducted Ducted Inverter Primary series 48000 Btu RPIL-6.0UFE1NH + RAS-6.0UFESNH1 R-32 is backordered and will ship as soon as it is back in stock.
Couldn't load pickup availability
How shipping works
How shipping works
I costi di spedizione variano a seconda del peso e della modalità di spedizione dell'ordine.
I nostri servizi di spedizione:
- Spedizione standard: consegna stimata dai 2 ai 5 giorni lavorativi
- Spedizione Premium: consegna garantita in 24 ore lavorative
- Spedizione Premium + Consegna al piano: consegna garantita in 24 ore lavorative
Consulta le tabelle per i prezzi della spedizione standard per l'Italia e per le Isole Minori e Zone Disagiate.
Per ulteriori dettagli sulla Spedizione Premium, consulta la pagina di spedizione premium.
Servizio clienti
Servizio clienti
Il nostro servizio di assistenza è dedicato a fornire supporto ai nostri clienti per qualsiasi problema o domanda che possano avere prima o dopo l’acquisto dei nostri prodotti.
Utilizza il canale di comunicazione diretta per parlare con un nostro operatore, oppure inviaci una mail ad uno degli indirizzi elencati nella pagina contattaci.
Il nostro team di assistenza clienti è composto da professionisti altamente qualificati e sempre pronti ad aiutare i clienti a risolvere qualsiasi problema o rispondere a qualsiasi domanda in modo rapido ed efficiente. Ci impegniamo a garantire la massima soddisfazione del cliente e a fornire un servizio di assistenza post-vendita di altissima qualità. Quindi, se hai bisogno di assistenza, non esitare a contattarci; saremo lieti di aiutarti in ogni modo possibile.
Description
Description
- Indoor unit catalog code: RPIH-6.0UFE1NH
- Outdoor unit catalog code: RAS-6.0UFESNH1
- Power: 48000 Btu; 6 HP
Energy efficiency
- SEER: 5.94
- SCOP: 3.70
- Energy efficiency class in cooling: -
- Heating energy efficiency class: -
- Cooling capacity: 14.19 kW
- Heating capacity: 16.13 kW
- Cooling absorption: 4.78 kW
- Heating absorption: 4.65 kW
- Indoor unit treated air: 2200 m 3 /h
- Indoor unit sound power level: 77 dB(A)
- External unit sound power level: 76 dB(A)
- Indoor unit sound pressure level: 42 ~ 47 dB(A)
- External unit sound pressure level: 62 dB(A)
Electrical Data
- Power (V,Hz, Ø): 220~240/50/1
- Refrigerant gas: R32
- Operating range
- - Cooling: -15° ~ 48°C
- - Heating: -15° ~ 24°C
- Liquid pipe diameter: 9.52 mm (3/8")
- Gas pipe diameter: 19.05 mm (3/4")
- Maximum pipe length: 50 m
- Maximum height difference internal unit / external unit: 30 m
Dimensions and weight
- Indoor unit dimensions (WxHxD): 1300x350x800 mm
- Indoor unit weight: 51.0 kg
- External unit dimensions (WxHxD): 950x1386x340 mm
- External unit weight: 101.50 kg
Hitachi Primairy ductable The best quality/price ratio
Designed for restaurants, hotels, apartments and shops. The indoor units are suitable for medium to large spaces. Rapid cooling and heating, to ensure a comfortable and silent environment. It provides year-round comfort by operating in heating up to -15°C outside and in cooling up to 48°C outside.
Commercial monosplits in heat pump with R32 refrigerant
Primairy R-32 is the range of commercial monosplits designed for the "primary" needs of small businesses and people who live and work in medium-sized spaces.
Efficiency and energy saving
The use of R32 refrigerant, which reduces the environmental impact by 2/3 compared to R410a, contributes to improving cooling and heating efficiencies
Guaranteed service continuity
In the event of a power outage, PRIMAIRY R32 automatically restarts at the conditions set before the outage. Automatic refrigerant quantity control ensures continuous system performance. When the refrigerant volume drops below 30%, an automatic alert with the anomaly code is displayed on the wall control, signaling the need for assistance service intervention
For all the distance you need
The range of ducted internal units allows the installation of the external unit on the roof of the building at a high refrigeration distance from the internal unit. Allowing refrigeration lengths of up to 50 meters and a height difference of 30 metres. The units are pre-charged for a length of 5m beyond which the additional charge is 28 g/m
Automatic restart following a power failure
As soon as the power supply is restored following an interruption, the systems automatically resume working at the previously set conditions. The function is available in the wall control configuration
Integrated condensate drain pump
The useful lift of 700 mm allows the unit to be integrated into most projects thanks also to a large integrated condensate collection tray
Wide external static pressure range
In the case of applications with long ducts or in multi-zone applications, it is possible to select a static pressure value within a wide range. Starting from the RPIH-3.5 internal unit the maximum static head is equal to 120 Pa
Oil Trap
If the internal unit is installed at a height more than 5m lower than the external unit, it is necessary to provide an oil siphon every 5m of height difference on the gas pipe
Pre-cut for fresh air intake
Indoor units from 3.0 HP up to 4.0 HP have an intake point for fresh air and this helps maintain good air quality within the air-conditioned environment. The dimensions of the circular pre-cut are 65 mm (3.0 HP) and 125 mm (3.5 - 4.0 HP)
Flexibility of air intake from the bottom or rear side
The possibility of changing the position of the intake grille allows for great flexibility, allowing for simple and quick installation
Product Warranty: All products on sale on our site are new and packaged. The warranty on this item is 24 months from the date of purchase.
Scheda Tecnica
Scheda Tecnica
- peso: 150.0 kg
- classe energetica raffreddamento: A++
- classe energetica riscaldamento: A
- gas: R-32
- marca: Hitachi
- metri quadri : 160 - 180 mq
- modello: RPIL-6.0UFE1NH + RAS-6.0UFESNH1_1
- potenza btu: 48000
- superficie riscaldabile mq: 140